visibility packet-capture global-templates template trigger-sys-obj-stats-change system-ip-threat-list

Configure triggers for system.ip-threat-list object

system-ip-threat-list Specification

Parameter Value
Type Configuration Resource
Element Name system-ip-threat-list
Element URI /axapi/v3/visibility/packet-capture/global-templates/template/{name}/trigger-sys-obj-stats-change/system-ip-threat-list
Element Attributes system-ip-threat-list_attributes
Partition Visibility shared
Schema system-ip-threat-list schema

Operations Allowed:

OperationMethodURIPayload

Create Object

POST

/axapi/v3/visibility/packet-capture/global-templates/template/{name}/trigger-sys-obj-stats-change/system-ip-threat-list

system-ip-threat-list attributes

Get Object

GET

/axapi/v3/visibility/packet-capture/global-templates/template/{name}/trigger-sys-obj-stats-change/system-ip-threat-list

system-ip-threat-list attributes

Modify Object

POST

/axapi/v3/visibility/packet-capture/global-templates/template/{name}/trigger-sys-obj-stats-change/system-ip-threat-list

system-ip-threat-list attributes

Replace Object

PUT

/axapi/v3/visibility/packet-capture/global-templates/template/{name}/trigger-sys-obj-stats-change/system-ip-threat-list

system-ip-threat-list attributes

Delete Object

DELETE

/axapi/v3/visibility/packet-capture/global-templates/template/{name}/trigger-sys-obj-stats-change/system-ip-threat-list

system-ip-threat-list attributes

system-ip-threat-list attributes

trigger-stats-inc

trigger-stats-rate

uuid

Description uuid of the object

Type: string

Maximum Length: 64 characters

Maximum Length: 1 characters

trigger-stats-inc

Specification Value
Type object

error_out_of_memory

Description Enable automatic packet-capture for Out of memory Error

Type: boolean

Supported Values: true, false, 1, 0

Default: 0

error_out_of_spe_entries

Description Enable automatic packet-capture for Out of SPE Entries Error

Type: boolean

Supported Values: true, false, 1, 0

Default: 0

uuid

Description uuid of the object

Type: string

Maximum Length: 64 characters

Maximum Length: 1 characters

trigger-stats-rate

Specification Value
Type object

duration

Description Time in seconds to look for the anomaly, default is 60

Type: number

Range: 1-250

Default: 60

error_out_of_memory

Description Enable automatic packet-capture for Out of memory Error

Type: boolean

Supported Values: true, false, 1, 0

Default: 0

error_out_of_spe_entries

Description Enable automatic packet-capture for Out of SPE Entries Error

Type: boolean

Supported Values: true, false, 1, 0

Default: 0

threshold-exceeded-by

Description Set the threshold to the number of times greater than the previous duration to start the capture, default is 5

Type: number

Range: 0-100

Default: 5

uuid

Description uuid of the object

Type: string

Maximum Length: 64 characters

Maximum Length: 1 characters