visibility packet-capture global-templates template trigger-sys-obj-stats-change fw-gtp

Configure triggers for fw.gtp object

fw-gtp Specification

Parameter Value
Type Configuration Resource
Element Name fw-gtp
Element URI /axapi/v3/visibility/packet-capture/global-templates/template/{name}/trigger-sys-obj-stats-change/fw-gtp
Element Attributes fw-gtp_attributes
Partition Visibility shared
Schema fw-gtp schema

Operations Allowed:

OperationMethodURIPayload

Create Object

POST

/axapi/v3/visibility/packet-capture/global-templates/template/{name}/trigger-sys-obj-stats-change/fw-gtp

fw-gtp attributes

Get Object

GET

/axapi/v3/visibility/packet-capture/global-templates/template/{name}/trigger-sys-obj-stats-change/fw-gtp

fw-gtp attributes

Modify Object

POST

/axapi/v3/visibility/packet-capture/global-templates/template/{name}/trigger-sys-obj-stats-change/fw-gtp

fw-gtp attributes

Replace Object

PUT

/axapi/v3/visibility/packet-capture/global-templates/template/{name}/trigger-sys-obj-stats-change/fw-gtp

fw-gtp attributes

Delete Object

DELETE

/axapi/v3/visibility/packet-capture/global-templates/template/{name}/trigger-sys-obj-stats-change/fw-gtp

fw-gtp attributes

fw-gtp attributes

trigger-stats-inc

Description: trigger-stats-inc is a JSON Block. Please see below for trigger-stats-inc

Type: Object

Reference Object: /axapi/v3/visibility/packet-capture/global-templates/template/{name}/trigger-sys-obj-stats-change/fw-gtp/trigger-stats-inc

trigger-stats-rate

Description: trigger-stats-rate is a JSON Block. Please see below for trigger-stats-rate

Type: Object

Reference Object: /axapi/v3/visibility/packet-capture/global-templates/template/{name}/trigger-sys-obj-stats-change/fw-gtp/trigger-stats-rate

uuid

Description uuid of the object

Type: string

Maximum Length: 64 characters

Maximum Length: 1 characters

trigger-stats-inc

Specification Value
Type object

gtp-c-ref-count-smp-exceeded

Description Enable automatic packet-capture for GTP-C session count on C-smp exceeded 2

Type: boolean

Supported Values: true, false, 1, 0

Default: 0

gtp-rate-limit-entry-create-failure

Description Enable automatic packet-capture for GTP Rate Limit Entry Create Failure

Type: boolean

Supported Values: true, false, 1, 0

Default: 0

gtp-rate-limit-smp-create-failure

Description Enable automatic packet-capture for GTP Rate Limit SMP Create Failure

Type: boolean

Supported Values: true, false, 1, 0

Default: 0

gtp-rate-limit-t3-ctr-create-failure

Description Enable automatic packet-capture for GTP Rate Limit Dynamic Counters Create Failure

Type: boolean

Supported Values: true, false, 1, 0

Default: 0

gtp-smp-check-failed

Description Enable automatic packet-capture for GTP SMP check Failed

Type: boolean

Supported Values: true, false, 1, 0

Default: 0

gtp-smp-dec-sess-count-check-failed

Description Enable automatic packet-capture for GTP-U session count is 0 in GTP-C SMP

Type: boolean

Supported Values: true, false, 1, 0

Default: 0

gtp-smp-path-check-failed

Description Enable automatic packet-capture for GTP SMP PATH check Failed

Type: boolean

Supported Values: true, false, 1, 0

Default: 0

gtp-smp-session-count-check-failed

Description Enable automatic packet-capture for GTP-U session count is not in range of 0-11 in GTP-C SMP

Type: boolean

Supported Values: true, false, 1, 0

Default: 0

gtp-tunnel-rate-limit-entry-create-fail

Description Enable automatic packet-capture for GTP Tunnel Level Rate Limit Entry Create Failure

Type: boolean

Supported Values: true, false, 1, 0

Default: 0

gtp-u-smp-in-rml-with-sess

Description Enable automatic packet-capture for GTP-U smp is marked RML with U-session

Type: boolean

Supported Values: true, false, 1, 0

Default: 0

out-of-session-memory

Description Enable automatic packet-capture for Out of Tunnel Memory

Type: boolean

Supported Values: true, false, 1, 0

Default: 0

uuid

Description uuid of the object

Type: string

Maximum Length: 64 characters

Maximum Length: 1 characters

trigger-stats-rate

Specification Value
Type object

duration

Description Time in seconds to look for the anomaly, default is 60

Type: number

Range: 1-250

Default: 60

gtp-c-ref-count-smp-exceeded

Description Enable automatic packet-capture for GTP-C session count on C-smp exceeded 2

Type: boolean

Supported Values: true, false, 1, 0

Default: 0

gtp-rate-limit-entry-create-failure

Description Enable automatic packet-capture for GTP Rate Limit Entry Create Failure

Type: boolean

Supported Values: true, false, 1, 0

Default: 0

gtp-rate-limit-smp-create-failure

Description Enable automatic packet-capture for GTP Rate Limit SMP Create Failure

Type: boolean

Supported Values: true, false, 1, 0

Default: 0

gtp-rate-limit-t3-ctr-create-failure

Description Enable automatic packet-capture for GTP Rate Limit Dynamic Counters Create Failure

Type: boolean

Supported Values: true, false, 1, 0

Default: 0

gtp-smp-check-failed

Description Enable automatic packet-capture for GTP SMP check Failed

Type: boolean

Supported Values: true, false, 1, 0

Default: 0

gtp-smp-dec-sess-count-check-failed

Description Enable automatic packet-capture for GTP-U session count is 0 in GTP-C SMP

Type: boolean

Supported Values: true, false, 1, 0

Default: 0

gtp-smp-path-check-failed

Description Enable automatic packet-capture for GTP SMP PATH check Failed

Type: boolean

Supported Values: true, false, 1, 0

Default: 0

gtp-smp-session-count-check-failed

Description Enable automatic packet-capture for GTP-U session count is not in range of 0-11 in GTP-C SMP

Type: boolean

Supported Values: true, false, 1, 0

Default: 0

gtp-tunnel-rate-limit-entry-create-fail

Description Enable automatic packet-capture for GTP Tunnel Level Rate Limit Entry Create Failure

Type: boolean

Supported Values: true, false, 1, 0

Default: 0

gtp-u-smp-in-rml-with-sess

Description Enable automatic packet-capture for GTP-U smp is marked RML with U-session

Type: boolean

Supported Values: true, false, 1, 0

Default: 0

out-of-session-memory

Description Enable automatic packet-capture for Out of Tunnel Memory

Type: boolean

Supported Values: true, false, 1, 0

Default: 0

threshold-exceeded-by

Description Set the threshold to the number of times greater than the previous duration to start the capture, default is 5

Type: number

Range: 0-100

Default: 5

uuid

Description uuid of the object

Type: string

Maximum Length: 64 characters

Maximum Length: 1 characters