visibility packet-capture global-templates template trigger-sys-obj-stats-change fw-gtp¶
Configure triggers for fw.gtp object
fw-gtp Specification¶
Parameter Value Type Configuration Resource Element Name fw-gtp Element URI /axapi/v3/visibility/packet-capture/global-templates/template/{name}/trigger-sys-obj-stats-change/fw-gtp Element Attributes fw-gtp_attributes Partition Visibility shared Schema fw-gtp schema
Operations Allowed:
Operation | Method | URI | Payload | |
---|---|---|---|---|
Create Object | POST | /axapi/v3/visibility/packet-capture/global-templates/template/{name}/trigger-sys-obj-stats-change/fw-gtp | ||
Get Object | GET | /axapi/v3/visibility/packet-capture/global-templates/template/{name}/trigger-sys-obj-stats-change/fw-gtp | ||
Modify Object | POST | /axapi/v3/visibility/packet-capture/global-templates/template/{name}/trigger-sys-obj-stats-change/fw-gtp | ||
Replace Object | PUT | /axapi/v3/visibility/packet-capture/global-templates/template/{name}/trigger-sys-obj-stats-change/fw-gtp | ||
Delete Object | DELETE | /axapi/v3/visibility/packet-capture/global-templates/template/{name}/trigger-sys-obj-stats-change/fw-gtp |
fw-gtp attributes¶
trigger-stats-inc
Description: trigger-stats-inc is a JSON Block. Please see below for trigger-stats-inc
Type: Object
Reference Object: /axapi/v3/visibility/packet-capture/global-templates/template/{name}/trigger-sys-obj-stats-change/fw-gtp/trigger-stats-inc
trigger-stats-rate
Description: trigger-stats-rate is a JSON Block. Please see below for trigger-stats-rate
Type: Object
Reference Object: /axapi/v3/visibility/packet-capture/global-templates/template/{name}/trigger-sys-obj-stats-change/fw-gtp/trigger-stats-rate
uuid
Description uuid of the object
Type: string
Maximum Length: 64 characters
Maximum Length: 1 characters
trigger-stats-inc¶
Specification Value Type object gtp-c-ref-count-smp-exceeded
Description Enable automatic packet-capture for GTP-C session count on C-smp exceeded 2
Type: boolean
Supported Values: true, false, 1, 0
Default: 0
gtp-rate-limit-entry-create-failure
Description Enable automatic packet-capture for GTP Rate Limit Entry Create Failure
Type: boolean
Supported Values: true, false, 1, 0
Default: 0
gtp-rate-limit-smp-create-failure
Description Enable automatic packet-capture for GTP Rate Limit SMP Create Failure
Type: boolean
Supported Values: true, false, 1, 0
Default: 0
gtp-rate-limit-t3-ctr-create-failure
Description Enable automatic packet-capture for GTP Rate Limit Dynamic Counters Create Failure
Type: boolean
Supported Values: true, false, 1, 0
Default: 0
gtp-smp-check-failed
Description Enable automatic packet-capture for GTP SMP check Failed
Type: boolean
Supported Values: true, false, 1, 0
Default: 0
gtp-smp-dec-sess-count-check-failed
Description Enable automatic packet-capture for GTP-U session count is 0 in GTP-C SMP
Type: boolean
Supported Values: true, false, 1, 0
Default: 0
gtp-smp-path-check-failed
Description Enable automatic packet-capture for GTP SMP PATH check Failed
Type: boolean
Supported Values: true, false, 1, 0
Default: 0
gtp-smp-session-count-check-failed
Description Enable automatic packet-capture for GTP-U session count is not in range of 0-11 in GTP-C SMP
Type: boolean
Supported Values: true, false, 1, 0
Default: 0
gtp-tunnel-rate-limit-entry-create-fail
Description Enable automatic packet-capture for GTP Tunnel Level Rate Limit Entry Create Failure
Type: boolean
Supported Values: true, false, 1, 0
Default: 0
gtp-u-smp-in-rml-with-sess
Description Enable automatic packet-capture for GTP-U smp is marked RML with U-session
Type: boolean
Supported Values: true, false, 1, 0
Default: 0
out-of-session-memory
Description Enable automatic packet-capture for Out of Tunnel Memory
Type: boolean
Supported Values: true, false, 1, 0
Default: 0
uuid
Description uuid of the object
Type: string
Maximum Length: 64 characters
Maximum Length: 1 characters
trigger-stats-rate¶
Specification Value Type object duration
Description Time in seconds to look for the anomaly, default is 60
Type: number
Range: 1-250
Default: 60
gtp-c-ref-count-smp-exceeded
Description Enable automatic packet-capture for GTP-C session count on C-smp exceeded 2
Type: boolean
Supported Values: true, false, 1, 0
Default: 0
gtp-rate-limit-entry-create-failure
Description Enable automatic packet-capture for GTP Rate Limit Entry Create Failure
Type: boolean
Supported Values: true, false, 1, 0
Default: 0
gtp-rate-limit-smp-create-failure
Description Enable automatic packet-capture for GTP Rate Limit SMP Create Failure
Type: boolean
Supported Values: true, false, 1, 0
Default: 0
gtp-rate-limit-t3-ctr-create-failure
Description Enable automatic packet-capture for GTP Rate Limit Dynamic Counters Create Failure
Type: boolean
Supported Values: true, false, 1, 0
Default: 0
gtp-smp-check-failed
Description Enable automatic packet-capture for GTP SMP check Failed
Type: boolean
Supported Values: true, false, 1, 0
Default: 0
gtp-smp-dec-sess-count-check-failed
Description Enable automatic packet-capture for GTP-U session count is 0 in GTP-C SMP
Type: boolean
Supported Values: true, false, 1, 0
Default: 0
gtp-smp-path-check-failed
Description Enable automatic packet-capture for GTP SMP PATH check Failed
Type: boolean
Supported Values: true, false, 1, 0
Default: 0
gtp-smp-session-count-check-failed
Description Enable automatic packet-capture for GTP-U session count is not in range of 0-11 in GTP-C SMP
Type: boolean
Supported Values: true, false, 1, 0
Default: 0
gtp-tunnel-rate-limit-entry-create-fail
Description Enable automatic packet-capture for GTP Tunnel Level Rate Limit Entry Create Failure
Type: boolean
Supported Values: true, false, 1, 0
Default: 0
gtp-u-smp-in-rml-with-sess
Description Enable automatic packet-capture for GTP-U smp is marked RML with U-session
Type: boolean
Supported Values: true, false, 1, 0
Default: 0
out-of-session-memory
Description Enable automatic packet-capture for Out of Tunnel Memory
Type: boolean
Supported Values: true, false, 1, 0
Default: 0
threshold-exceeded-by
Description Set the threshold to the number of times greater than the previous duration to start the capture, default is 5
Type: number
Range: 0-100
Default: 5
uuid
Description uuid of the object
Type: string
Maximum Length: 64 characters
Maximum Length: 1 characters