Configure Detection

To configure a detector, do the following:

  1. Go to Devices >> Device List .
  2. For the TPS device that you wish to configure as a detector, under Actions, click Details and select Configure Detection.

    General Settings

    Under General Settings, the name of the device and detector type is displayed by default.

    Detector xFlow Settings

    Table 146 : Information on Detector xFlow Settings

    Field

    Purpose

    sFlow Receiving Port

    Enter a port that is used to receive the sFlow traffic which needs to be monitored.

    NetFlow Receiving Port

    Enter a port that is used to receive NetFlow traffic which needs to be monitored.

    Detection Window Size

    Enter an xFlow sample receiving interval.

    Initial Learning Interval

    Enter an initial learning period to understand the traffic patterns.

  1. Add the Remote Agents information to determine the routers from where xFlow samples are sent. Click + and add the following information:

    Table 147 : Information on Remote Agents

    Field

    Purpose

    Agent name

    Enter the name of the router. For example, edge-router-ax2500.

    IP Address

    Enter the IP address of the router.

    sFlow

    Select the flow technology that the detector supports.

    Netflow

    Select the flow technology that the detector supports.

    Netflow Sampling Rate

    If Netflow is selected as the flow technology, set the sampling rate of packets. For example, if the sampling rate is 1, every packet is sampled for the detection process.

  2. Click Submit.

COMPANY INFORMATION: Copyright © 2024 A10 Networks, Inc. All Rights Reserved. Legal Notice