sflow setting¶
Configure sFlow
setting Specification¶
Parameter Value Type Configuration Resource Element Name setting Element URI /axapi/v3/sflow/setting Element Attributes setting_attributes Partition Visibility shared Schema setting schema
Operations Allowed:
Operation | Method | URI | Payload | |
---|---|---|---|---|
Create Object | POST | /axapi/v3/sflow/setting | ||
Get Object | GET | /axapi/v3/sflow/setting | ||
Modify Object | POST | /axapi/v3/sflow/setting | ||
Replace Object | PUT | /axapi/v3/sflow/setting | ||
Delete Object | DELETE | /axapi/v3/sflow/setting | ||
setting attributes¶
counter-polling-interval
Description sFlow counter polling interval, default is 10
Type: number
Range: 1-200
Default: 10
local-collection
Description Enable local sflow collection
Type: boolean
Supported Values: true, false, 1, 0
Default: 0
max-header
Description Configure maximum number of bytes that should be copied from a sampled packet (default: 128) (The maximum number of bytes (Default: 128))
Type: number
Range: 14-512
Default: 128
packet-sampling-rate
Description sFlow packet sampling rate, default is 1000
Type: number
Range: 10-1000000
Default: 1000
source-ip-use-mgmt
Description Use management interface’s IP address for source IP of sFlow packets
Type: boolean
Supported Values: true, false, 1, 0
Default: 0
uuid
Description uuid of the object
Type: string
Maximum Length: 64 characters
Maximum Length: 1 characters