harmony-controller¶
Harmony controller information
harmony-controller Specification¶
Type Intermediate Resource Element Name harmony-controller Element URI /axapi/v3/harmony-controller Element Attributes harmony-controller_attributes Schema harmony-controller schema
Operations Allowed:
Operation | Method | URI | Payload | |
---|---|---|---|---|
Get Object | GET | /axapi/v3/harmony-controller | harmony-controller_attributes |
harmony-controller attributes¶
config-replace
Description: config-replace is a JSON Block. Please see below for config-replace
Type: Object
Reference Object: /axapi/v3/harmony-controller/config-replace
partition-tenant-info
Description: partition-tenant-info is a JSON Block. Please see below for partition-tenant-info
Type: Object
Reference Object: /axapi/v3/harmony-controller/partition-tenant-info
profile
Description: profile is a JSON Block. Please see below for profile
Type: Object
Reference Object: /axapi/v3/harmony-controller/profile
telemetry
Description: telemetry is a JSON Block. Please see below for telemetry
Type: Object
Reference Object: /axapi/v3/harmony-controller/telemetry
tunnel-stats
Description: tunnel-stats is a JSON Block. Please see below for tunnel-stats
Type: Object
Reference Object: /axapi/v3/harmony-controller/tunnel-stats
profile¶
Specification Type object action
Description ‘register’: Register the device to the controller; ‘deregister’: Deregister the device from controller;
Type: string
Supported Values: register, deregister
auto-restart-action
Description ‘enable’: enable auto analytics bus restart, default behavior is enable; ‘disable’: disable auto analytics bus restart;
Type: string
Supported Values: enable, disable
Default: enable
availability-zone
Description availablity zone of the thunder-device
Type: string
Format: string-rlx
Maximum Length: 128 characters
Maximum Length: 1 characters
cluster-id
Description id for the cluster in harmony controller, typically an uuid
Type: string
Maximum Length: 128 characters
Maximum Length: 1 characters
cluster-name
Description name of cluster in harmony controller that this device is a member of
Type: string
Maximum Length: 128 characters
Maximum Length: 1 characters
host
Description Set harmony controller host adddress
Type: string
Format: host
Mutual Exclusion: host and host-ipv6 are mutually exclusive
host-ipv6
Description IPV6 address or FQDN for the host
Type: string
Maximum Length: 128 characters
Maximum Length: 1 characters
Mutual Exclusion: host-ipv6 and host are mutually exclusive
interval
Description auto analytics bus restart time interval in mins, default is 3 mins
Type: number
Range: 1-15
Default: 3
password-encrypted
Description Do NOT use this option manually. (This is an A10 reserved keyword.) (The ENCRYPTED secret string)port
Description Set port for remote Harmony Controller
Type: number
Range: 1-32767
provider
Description provider for the harmony-controller
Type: string
Maximum Length: 128 characters
Maximum Length: 1 characters
re-sync
Description: re-sync is a JSON Block. Please see below for profile_re-sync
Type: Object
Reference Object: /axapi/v3/harmony-controller/profile/re-sync
region
Description region of the thunder-device
Type: string
Format: string-rlx
Maximum Length: 128 characters
Maximum Length: 1 characters
secret-value
Description Specify the password for the user
Type: string
Format: password
Maximum Length: 128 characters
Maximum Length: 1 characters
thunder-mgmt-ip
Description: thunder-mgmt-ip is a JSON Block. Please see below for profile_thunder-mgmt-ip
Type: Object
Reference Object: /axapi/v3/harmony-controller/profile/thunder-mgmt-ip
tunnel
Description: tunnel is a JSON Block. Please see below for profile_tunnel
Type: Object
Reference Object: /axapi/v3/harmony-controller/profile/tunnel
use-mgmt-port
Description Use management port for connections
Type: boolean
Supported Values: true, false, 1, 0
Default: 0
user-name
Description user-name for the tenant
Type: string
Format: string-rlx
Maximum Length: 128 characters
Maximum Length: 1 characters
uuid
Description uuid of the object
Type: string
Maximum Length: 64 characters
Maximum Length: 1 characters
profile_re-sync¶
Specification Type object analytics-bus
Description re-sync analtyics bus connections
Type: boolean
Supported Values: true, false, 1, 0
Default: 0
schema-registry
Description re-sync the schema registry
Type: boolean
Supported Values: true, false, 1, 0
Default: 0
profile_tunnel¶
Specification Type object action
Description ‘enable’: Tunnel Enable; ‘disable’: Tunnel Disable;
Type: string
Supported Values: enable, disable
Default: disable
uuid
Description uuid of the object
Type: string
Maximum Length: 64 characters
Maximum Length: 1 characters
profile_thunder-mgmt-ip¶
Specification Type object ip-address
Description IP address (IPv4 address)
Type: string
Format: ipv4-address
Mutual Exclusion: ip-address and ipv6-addr are mutually exclusive
ipv6-addr
Description IPV6 address for the host
Type: string
Format: ipv6-address
Mutual Exclusion: ipv6-addr and ip-address are mutually exclusive
uuid
Description uuid of the object
Type: string
Maximum Length: 64 characters
Maximum Length: 1 characters
tunnel-stats¶
Specification Type object uuid
Description uuid of the object
Type: string
Maximum Length: 64 characters
Maximum Length: 1 characters
config-replace¶
Specification Type object status
Description ‘enable’: enable config replace mode; ‘disable’: disable config replace mode;
Type: string
Supported Values: enable, disable
Default: disable
uuid
Description uuid of the object
Type: string
Maximum Length: 64 characters
Maximum Length: 1 characters
telemetry¶
Specification Type object log-rate
Description Max number of session logs sent by the partition per second
Type: number
Range: 0-10000
Default: 10
uuid
Description uuid of the object
Type: string
Maximum Length: 64 characters
Maximum Length: 1 characters
partition-tenant-info¶
Specification Type object uuid
Description uuid of the object
Type: string
Maximum Length: 64 characters